What the cold actually does to a heat pump here
Heat runs nine months a year in Rutland County, September through May. The overnight low averages 12°F in December, January and February. About 165 nights a year end up at or below freezing, over half the nights the heat runs at all. About 19 of those nights drop to 0°F or below.
A standard heat pump starts losing ground before it gets anywhere near that cold. Below 40°F its heat output falls short of its rated capacity. Below about 35°F it often needs backup heat to keep up. Every one of the 165 freezing nights here is colder than both marks. That is not a rare cold snap for this county. That is most of the winter.
This does not mean a heat pump will leave you cold. Cold climate models are built and tested for exactly this: to make at least 1.75 units of heat per unit of electricity at 5°F, and hold at least 70 percent of their 47°F capacity at that temperature, checked by outside testing. Field tests of these units in occupied homes found backup heat carried only a small share of the load between 0°F and 35°F, and running on backup alone was rare even below 0°F. A cold climate heat pump, sized for this county, can carry a Rutland County winter. A standard one, built only to the federal minimum, is the one that struggles once the nights turn cold here, and most of them do.