Can a heat pump keep up with winter here
Winters in Chittenden County decide this more than the cost numbers do. The heat runs nine months a year here, September through May, and the overnight low averages 12°F across December, January and February. That is well below the two marks that matter for a heat pump. A standard heat pump starts losing its rated output below 40°F, and below about 35°F it often needs backup heat to make up the difference. Here, every one of the roughly 150 nights a year that drop to freezing or below is under both marks already, before it even gets properly cold.
So on an average winter night, a standard heat pump is working below its rating and likely leaning on backup heat to hold the house at temperature. About 18 nights a year here reach 0°F or below, and that is where a plain heat pump falls hardest. If you go this route, look for one with the ENERGY STAR Cold Climate rating. To earn it, a heat pump has to make at least 1.75 units of heat per unit of electricity at 5°F and hold on to at least 70 percent of its 47°F capacity at that temperature, checked by independent testing, which is a real step up from the federal minimum unit the running-cost numbers above are built on.
A cold-climate heat pump does not eliminate backup heat, it just needs it less. A two winter field test of prototype cold-climate heat pumps in occupied homes found backup heat covered only a small share of the total heat used between 0°F and 35°F, and the system running on backup alone was rare even above 0°F. That is a different machine than the federal-minimum unit priced in the running-cost band, and a different bet than a standard heat pump.